If you own a battery and an inverter, you must wonder how long they can support a load. The real answer is: it depends on 4 factors. These are battery capacity, load, battery type, and inverter. This article explains the formula and shows a clear example. It is written for buyers who plan solar and storage projects.

Wall-mounted lithium battery storage unit beside a solar inverter

Inverter battery runtime: direct answer

Runtime is the number of hours a battery can supply an AC load through an inverter. It is not fixed. Double the load and you roughly halve the runtime. Use a larger battery and the runtime grows.

The core idea is energy. A battery stores a certain amount of energy. The load consumes energy at a certain rate. Divide the energy by the rate and you get the hours.

The inverter battery backup time formula

Use this formula for a quick estimate:

Runtime (hours) = Battery Ah × Battery V × DoD × Inverter efficiency ÷ Load (watts)

Here is the meaning of each part:

  • Battery Ah: the amp-hour rating printed on the battery.
  • Battery V: the nominal voltage, usually 12V, 24V, or 48V.
  • DoD: the share of the battery you can safely use.
  • Inverter efficiency: the share of DC that becomes AC, usually 85% to 92%.
  • Load: the total number of watts running at the same time.

Do not overlook voltage. A 100Ah battery at 48V stores 4 times as much energy as a 100Ah battery at 12V.

How to calculate inverter battery backup: a practical example

Consider a 12V 100Ah lithium battery. It powers a 100W load through a 90% efficient inverter. The battery is LiFePO4, so you can use about 80% of it.

  1. Calculate the stored energy: 12 × 100 = 1,200 watt-hours.
  2. Apply DoD: 1,200 × 0.80 = 960 watt-hours.
  3. Apply efficiency: 960 × 0.90 = 864 watt-hours.
  4. Divide by the load: 864 ÷ 100 = 8.64 hours.

So the inverter runs for about 8.6 hours. If the load rises to 200W, the time drops to about 4.3 hours. The battery energy does not change. Only the rate of use changes.

Load (watts) Approx. runtime
100W 8.6 hours
200W 4.3 hours
400W 2.2 hours

Use the average running watts, not the peak. A refrigerator may spike at start-up but consume much less once running.

Battery depth of discharge and usable energy

Depth of discharge, or DoD, is how much of the battery you can use. You should not discharge a battery to zero in each cycle.

Lead-acid and tubular batteries usually allow about 50% DoD. Deeper discharge shortens their life. Lithium LiFePO4 cells often allow about 80% DoD. This is one reason lithium provides longer runtime for the same Ah rating.

For good planning, match the DoD to the battery type. Our comparison of LiFePO4 vs lead-acid batteries explains the trade-offs in detail.

How inverter efficiency changes the result

An inverter loses energy as heat. A 90% efficient unit wastes 10% of the energy leaving the battery. A lower-grade unit wastes more.

Efficiency also changes with the load. Most inverters peak near the middle of their range. A unit that is too large for the load may run less efficiently. Size the inverter to the actual load, not the largest appliance you own.

Lead acid vs lithium inverter battery runtime

Two batteries with the same Ah can provide very different runtimes. The reason lies in usable energy and efficiency.

  • Lead-acid: lower upfront cost, about 50% usable capacity, shorter cycle life.
  • LiFePO4: higher upfront cost, about 80% usable capacity, far more cycles.

For daily cycling, lithium often wins in cost over time. You replace it less often and use more of each charge. If you are unsure which to choose, our guide to how long solar batteries last provides more context.

Other factors that shorten actual runtime

The formula gives a clean number. The actual runtime is a little lower. Watch for these points:

  • Battery age: an old battery stores less than its rated Ah.
  • Cold weather: low temperature reduces available capacity.
  • Inverter idle draw: the inverter consumes power even at light load.
  • Cable losses: long or thin cables waste energy as heat.

Add a safety margin of 10% to 20% to your plan. This prevents your customer from running out of power too early.

Key takeaway

So, how long will an inverter last on a battery? Use battery Ah, voltage, DoD, and efficiency to find usable energy. Then divide by the actual load in watts. Check the battery type, age, and inverter size before you set a number.